Electrical Installation
thermoIMAGER TIM
The process interface can be activated choosing the following options:
Analog Input (AI): Emissivity, ambient temperature, reference temperature, flag control, triggered re
cording, triggered snapshots, triggered line scanner, uncommitted value
Analog Output (AO): Main area temperature, internal temperature, flag status, alarm, fail-safe
Digital Input (DI): Flag control, triggered recording, triggered snapshots, triggered line scanner
Fig. 18 Configuration process interface (PIF)
The standard process interface offers the following inputs and outputs:
Designation Description max. range
1/
status
AI Analog input 0 - 10 V
DI Digital input 24 V
AO Analog output 0 - 10 V
Alarm output 0/ 10 V
6.3 Industrial Process Interface (Optional)
For use in industrial environment an industrial process interface with 500 VAC
RMS
isolation voltage between
TIM and process is available (connection box with IP 65, 5 m, 10 m or 20 m standard or high temp cable for
camera connection, terminal for process integration), see Chap. A 6 (Industrial Process Interface).