Appendix F – TIM Interface
thermoIMAGER TIM 76
Appendix F – TIM Interface
12 V output:
With no load the isolated output voltage is about 12 V.
Isolation voltage to USB power: >1000 VDC
You can drive as maximum 10 mA from the 12 V out (pin 2) or from the analog output (pin 4).
The 12 V output has a 1 KOhm resistor in raw. You can directly connect a LED as a “camera is working”
indication.
Another possibility is the use of the voltage for the external emissivity setting: